产品详情
  • 产品名称:圣戈班Tygon ND-100-80医用透明软管

  • 产品型号:AAD04091
  • 产品厂商:圣戈班Saint-Gobain
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
AAD04091型号法国圣戈班Saint-Gobain ND-100-80医用软管,内径:0.25mm,外径:0.76mm,壁厚:0.25mm,每卷管长500Feet,原厂货源,全型号可选
详情介绍:

Tygon ND-100-80透明细管,可用于动脉及静脉输液,广泛应用于医院及实验室。软而富有弹性,同一条管可以与不同规格的针头相连接;同时,材质又有足够的刚性,确保不会爆裂。无毒、无热原,生物相容性符合USP Class VI标准。可高压mie菌、EtO、辐照或化学方法mie菌。


典型应用:静脉或动脉输注

增塑剂:TOTM


Tygon ND-100-80管订货信息:

型号

内径

外径

壁厚

管长

Feet

Inches

mm

Inches

mm

Inches

mm

AAD04091

0.01

0.25

0.03

0.76

0.01

0.25

500

AAD04103

0.02

0.51

0.06

1.52

0.02

0.51

500

AAD04119

0.03

0.76

0.09

2.29

0.03

0.76

500

AAD04127

0.04

1.02

0.07

1.78

0.015

0.38

500

AAD04133

0.05

1.27

0.09

2.29

0.02

0.51

500

广州市赛拓仪器科技有限公司代理经销法国Saint-Gobain圣戈班软管,tygon管,Versilon管型号齐全,大部分型号有现货,发货地为广州,订购前请详细沟通使用场景、货期、售价等信息。


TYGON R ND 10O-80, one of the medical industry's leading Non-DEHP tubing offerings, has been specifically formulated in a higherdurometer that makes it possible to produce smaller diameter tubings with a high resistance to kinking and collapse.


Characteristics

TYGONR ND 100-80 is available exclusively to medical device manufacturers in fiveextremely small sizes for use in their medical devices used in intravenous or intra-arterial infusion, and other surgical and hospital applications.It is rigid enough foreasy handling, yet soft enough to reduce problems with puncturing.

Since TYGONR ND 100-80 is thermoplastic in nature, it can be fabricated into

cannulas or protective sheath products using thermoforming and flaring techniques.


Based upon a unique chemistry developed by Saint-Gobain, TYGON' ND Series tubingwas formulated to be meet the requirements of Regulation(EC)1907/2006 on theRegistration, Evaluation, Authorization and Restriction of Chemicals(REACH)andRegulation(EU)2017/745 on medical devices(EU MDR) of not containing anyreportable substances or chemicals of concern.Every individual compound lot is tested to ensure DEHP levels are <1000 ppm. During the extrusion process, individualproduct dimensions are maintained and monitored through in-line micrometers andoff-line verification with computerized imaging equipment.


Consistent with many medical tubing market requirements,ND 100-80 material canbe effectively bonded/welded using the following methods: heat, electronic(RF)/ultrasonic, solvent and adhesive. Factors to be considered when selecting thecomponents include:security of the bond required, effect on the integrity of thematerials to be joined, and presence of residues or extractables that may affectbiocompatibility.When bonding procedures are not used, mechanical clamps arerecommended to provide secure attachment.


Biocompatibility

TYGONRND 10O-80 is made from a biocompatible, non-DEHP polymer material developed specifically for medical device needs.The product meets the requirementof the USP<88>, Plastic Class Vl criteria. lt has extremely good blood interactioncharacteristics, very low extractable in soapy water and refluxed water. This is rarefor a plasticized PVC as usually there will be an increase in extraction in one of thosemediums. lt is animal derivative free and also lead stabilizer free.

粤公网安备 44010602004867号